Vulnerabilities in the CA certificate download and the diagnostic log functionality affecting B/W small multifunction and single-function printers
Dear Customers,
We deeply appreciate your constant patronage to Konica Minolta products.
Two security vulnerabilities have been newly identified in the indicated models below.
This advisory provides an overview of the issues and the recommended countermeasures.
Please note that, at the time of publication, there have been no confirmed security incidents globally resulting from the exploitation of these vulnerabilities.
Overview of the vulnerabilities
CVE-ID | CVSS Assessment | Base Score | Vulnerabilities description |
CVE-2025-53869 | CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N | 6.3 | The set of root certificates used by the product may be replaced with a set of arbitrary certificates by a man-in-the-middle attack. (CWE-295: Improper certificate validation) |
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N | 3.7 | ||
CVE-2025-55704 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N | 6.9 | An attacker may obtain the logs of the affected product and obtain sensitive information within the logs. (CWE-912: Hidden Functionality) |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N | 5.3 |
Affected Models and the countermeasure firmware
Product name | Program name | Affected version | Fixed version |
bizhub 5021i | Firmware | 1.02 | 1.04 |
bizhub 5001i | Firmware | 1.03 | 1.05 |
bizhub 4221i | Firmware | 1.02 | 1.04 |
bizhub 4201i | Firmware | 1.02 | 1.04 |
bizhub 5020i | Main-Firmware | U2412241059 (Ver S)or earlier | U2505151336 (Ver T) or later |
Sub-Firmware | 1.15 or earlier | 1.16 or later | |
bizhub 5000i | Main-Firmware | 1.33 or earlier | 1.34 or later |
Sub-Firmware | 1.15 or earlier | 1.16 or later | |
bizhub 4020i | Main-Firmware | U2412241059 (Ver S)or earlier | U2505151336 (Ver T) or later |
Sub-Firmware | 1.15 or earlier | 1.16 or later | |
bizhub 4000i | Main-Firmware | 1.29 or earlier | 1.30 or later |
Sub-Firmware | 1.15 or earlier | 1.16 or later |
Remediation
Download the Firmware Update Tool from Download Centre and upgrade the firmware of your device.
General Security Recommendations
To ensure a secure operating posture for your multifunction devices, and to reduce exposure to the vulnerability described in this advisory, Konica Minolta strongly recommends applying the following configuration best practices:
Related Information
JVNVU#92878805
Contact
Should you require further clarification or assistance with implementing the recommended measures or applying the relevant firmware update, please contact your authorized Konica Minolta service representative.